Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 902
1.
J Am Heart Assoc ; 13(9): e032777, 2024 May 07.
Article En | MEDLINE | ID: mdl-38639357

BACKGROUND: A delayed and recurrent complete atrioventricular block (CAVB) is a life-threatening complication of transcatheter aortic valve replacement (TAVR). Post-TAVR evaluation may be important in predicting delayed and recurrent CAVB requiring permanent pacemaker implantation (PPI). The impact of new-onset right bundle-branch block (RBBB) after TAVR on PPI remains unknown. METHODS AND RESULTS: In total, 407 patients with aortic stenosis who underwent TAVR were included in this analysis. Intraprocedural CAVB was defined as CAVB that occurred during TAVR. A 12-lead ECG was evaluated at baseline, immediately after TAVR, on postoperative days 1 and 5, and according to the need to identify new-onset bundle-branch block (BBB) and CAVB after TAVR. Forty patients (9.8%) required PPI, 17 patients (4.2%) had persistent intraprocedural CAVB, and 23 (5.7%) had delayed or recurrent CAVB after TAVR. The rates of no new-onset BBB, new-onset left BBB, and new-onset RBBB were 65.1%, 26.8%, and 4.7%, respectively. Compared with patients without new-onset BBB and those with new-onset left BBB, the rate of PPI was higher in patients with new-onset RBBB (3.4% versus 5.6% versus 44.4%, P<0.0001). On post-TAVR evaluation in patients without persistent intraprocedural CAVB, the multivariate logistic regression analysis showed that new-onset RBBB was a statistically significant predictor of PPI compared with no new-onset BBB (odds ratio [OR], 18.0 [95% CI, 5.94-54.4]) in addition to the use of a self-expanding valve (OR, 2.97 [95% CI, 1.09-8.10]). CONCLUSIONS: Patients with new-onset RBBB after TAVR are at high risk for PPI.


Aortic Valve Stenosis , Bundle-Branch Block , Cardiac Pacing, Artificial , Electrocardiography , Pacemaker, Artificial , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Male , Female , Bundle-Branch Block/etiology , Bundle-Branch Block/therapy , Bundle-Branch Block/physiopathology , Bundle-Branch Block/diagnosis , Aortic Valve Stenosis/surgery , Aged, 80 and over , Aged , Cardiac Pacing, Artificial/adverse effects , Atrioventricular Block/therapy , Atrioventricular Block/etiology , Atrioventricular Block/diagnosis , Atrioventricular Block/physiopathology , Risk Factors , Retrospective Studies , Treatment Outcome , Time Factors , Postoperative Complications/etiology , Postoperative Complications/therapy , Postoperative Complications/diagnosis , Recurrence
2.
Glob Heart ; 19(1): 40, 2024.
Article En | MEDLINE | ID: mdl-38681972

Background: Previous registries have shown a younger average age at presentation with cardiovascular diseases in the Middle East (ME), but no study has examined atrioventricular block (AVB). Moreover, these comparisons are confounded by younger populations in the ME. We sought to describe the average age at presentation with AVB in ME and quantify the effect of being from ME, adjusted for the overall younger population. Methodology: This was a retrospective analysis of PANORAMA registries, which collected data on patients who underwent cardiac rhythm device placement worldwide. Countries with a median population age of ≤30 were considered 'young countries'. Multivariate linear regression was performed to assess the effect of being from ME, adjusted for being from a 'young country', on age at presentation with AVB. Results: The study included 5,259 AVB patients, with 640 (8.2%) from the ME. Mean age at presentation was seven years younger in ME than in other regions (62.9 ± 17.8 vs. 70 ± 14.1, P < 0.001). Being from a 'young country' was associated with 5.6 years younger age at presentation (95%CI -6.5--4.6), whereas being from ME was associated with 3.1 years younger age at presentation (95%CI -4.5--1.8), (P < 0.001 for both). Conclusion: The average age at presentation with AVB in the ME is seven years younger than in other regions. While this is mostly driven by the overall younger population, being from the ME appears to be independently associated with younger age. Determinants of the earlier presentation in ME need to be assessed, and care should be taken when applying international recommendations.


Atrioventricular Block , Registries , Humans , Atrioventricular Block/epidemiology , Atrioventricular Block/physiopathology , Middle East/epidemiology , Male , Female , Retrospective Studies , Middle Aged , Aged , Adult , Age Factors , Pacemaker, Artificial/statistics & numerical data , Defibrillators, Implantable/statistics & numerical data , Incidence , Age of Onset , Young Adult
4.
J Cardiovasc Electrophysiol ; 35(5): 906-915, 2024 May.
Article En | MEDLINE | ID: mdl-38433355

INTRODUCTION: Right ventricular (RV) pacing sometimes causes left ventricular (LV) systolic dysfunction, also known as pacing-induced cardiomyopathy (PICM). However, the association between specifically paced QRS morphology and PICM development has not been elucidated. This study aimed to investigate the association between paced QRS mimicking a complete left bundle branch block (CLBBB) and PICM development. METHODS: We retrospectively screened 2009 patients who underwent pacemaker implantation from 2010 to 2020 in seven institutions. Patients who received pacemakers for an advanced atrioventricular block or bradycardia with atrial fibrillation, baseline LV ejection fraction (LVEF) ≥ 50%, and echocardiogram recorded at least 6 months postimplantation were included. The paced QRS recorded immediately after implantation was analyzed. A CLBBB-like paced QRS was defined as meeting the CLBBB criteria of the American Heart Association/American College of Cardiology Foundation/Heart Rhythm Society in 2009. PICM was defined as a ≥10% LVEF decrease, resulting in an LVEF of <50%. RESULTS: Among the 270 patients analyzed, PICM was observed in 38. Baseline LVEF was lower in patients with PICM, and CLBBB-like paced QRS was frequently observed in PICM. Multivariate analysis revealed that low baseline LVEF (odds ratio [OR]: 0.93 per 1% increase, 95% confidence interval [CI]: 0.89-0.98, p = 0.006) and CLBBB-like paced QRS (OR: 2.69, 95% CI: 1.25-5.76, p = 0.011) were significantly associated with PICM development. CONCLUSION: CLBBB-like paced QRS may be a novel risk factor for PICM. RV pacing, which causes CLBBB-like QRS morphology, may need to be avoided, and patients with CLBBB-like paced QRS should be followed-up carefully.


Action Potentials , Bundle-Branch Block , Cardiac Pacing, Artificial , Cardiomyopathies , Electrocardiography , Heart Rate , Predictive Value of Tests , Stroke Volume , Ventricular Function, Left , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Atrioventricular Block/physiopathology , Atrioventricular Block/diagnosis , Atrioventricular Block/therapy , Atrioventricular Block/etiology , Bundle-Branch Block/physiopathology , Bundle-Branch Block/diagnosis , Bundle-Branch Block/therapy , Bundle-Branch Block/etiology , Cardiac Pacing, Artificial/adverse effects , Cardiomyopathies/physiopathology , Cardiomyopathies/etiology , Cardiomyopathies/therapy , Cardiomyopathies/diagnosis , Diagnosis, Differential , Retrospective Studies , Risk Assessment , Risk Factors , Time Factors , Treatment Outcome , Ventricular Function, Right
5.
Heart Rhythm ; 19(2): 318-329, 2022 02.
Article En | MEDLINE | ID: mdl-34678525

BACKGROUND: Electrical storm (ES) is a life-threatening emergency in patients at high risk of ventricular tachycardia/ventricular fibrillation (VF), but the pathophysiology and molecular basis are poorly understood. OBJECTIVE: The purpose of this study was to explore the electrophysiological substrate for experimental ES. METHODS: A model was created by inducing chronic complete atrioventricular block in defibrillator-implanted rabbits, which recapitulates QT prolongation, torsades des pointes (TdP), and VF episodes. RESULTS: Optical mapping revealed island-like regions with action potential duration (APD) prolongation in the left ventricle, leading to increased spatial APD dispersion, in rabbits with ES (defined as ≥3 VF episodes/24 h). The maximum APD and its dispersion correlated with the total number of VF episodes in vivo. TdP was initiated by an ectopic beat that failed to enter the island and formed a reentrant wave and perpetuated by rotors whose centers swirled in the periphery of the island. Epinephrine exacerbated the island by prolonging APD and enhancing APD dispersion, which was less evident after late Na+ current blockade with 10 µM ranolazine. Nonsustained ventricular tachycardia in a non-ES rabbit heart with homogeneous APD prolongation resulted from multiple foci with an electrocardiographic morphology different from TdP driven by drifting rotors in ES rabbit hearts. The neuronal Na+-channel subunit NaV1.8 was upregulated in ES rabbit left ventricular tissues and expressed within the myocardium corresponding to the island location in optically mapped ES rabbit hearts. The NaV1.8 blocker A-803467 (10 mg/kg, intravenously) attenuated QT prolongation and suppressed epinephrine-evoked TdP. CONCLUSION: A tissue island with enhanced refractoriness contributes to the generation of drifting rotors that underlies ES in this model. NaV1.8-mediated late Na+ current merits further investigation as a contributor to the substrate for ES.


Atrioventricular Block/physiopathology , Tachycardia, Ventricular/physiopathology , Torsades de Pointes/physiopathology , Action Potentials , Animals , Atrioventricular Block/drug therapy , Defibrillators, Implantable , Disease Models, Animal , Long QT Syndrome/physiopathology , Rabbits , Ranolazine/pharmacology
8.
Pacing Clin Electrophysiol ; 44(11): 1907-1917, 2021 Nov.
Article En | MEDLINE | ID: mdl-34520042

BACKGROUND: Permanent His-bundle pacing (HBP) is effective and safe; however, the success rate of HBP is low, especially in patients with infranodal block. This study aimed to assess the efficacy and feasibility of HBP implantation using an electrophysiological guided approach targeting a distal His-bundle electrogram (HBE) in patients with atrioventricular block (AVB). METHODS: Thirty-four consecutive patients with AVB (infranodal block in 28 patients) who underwent HBP were enrolled. During implantation, we attempted to target the distal part of the HBE (distal HBE) beyond the block site based on unipolar mapping. The His-capture threshold was evaluated for 1 year after implantation. RESULTS: HBP was achieved in 26 patients and in 21 patients (75%) with infranodal block. Detection of distal HBE was significantly higher in the successful HBP group than in the HBP failure group (65.4% vs. 0%, p = .001). Among 15 patients with intra-Hisian block, 14 patients (93%) successfully achieved HBP with distal HBE detection. During the 1-year follow-up period, an increase in His-capture threshold by ≥1.0 V at 1.0 ms occurred in five (19.2%) of 26 patients. The increased His-capture threshold group exhibited significantly less detection of distal HBE (20% vs. 76.2%; odds ratio 0.078, 95% confidence interval 0.07-0.87, p = .038) and a higher His-capture threshold at implantation (2.0 ± 1.1 V vs. 1.1 ± 0.9 V; odds ratio 1.702, 95% confidence interval 1.025-2.825, p = 0.04) than the non-increased His-capture threshold group. CONCLUSION: HBP implantation guided by distal HBE approach may be feasible with subsequent stable pacing in patients with intra-Hisian and atrioventricular nodal block.


Atrioventricular Block/physiopathology , Atrioventricular Block/therapy , Bundle of His/physiopathology , Cardiac Pacing, Artificial/methods , Electrophysiologic Techniques, Cardiac , Aged , Feasibility Studies , Female , Humans , Male
9.
PLoS Comput Biol ; 17(9): e1009361, 2021 09.
Article En | MEDLINE | ID: mdl-34550969

NEW & NOTEWORTHY: To the best of our knowledge, this is the first hemodynamic-based heart sound generation model embedded in a complete real-time computational model of the cardiovascular system. Simulated heart sounds are similar to experimental and clinical measurements, both quantitatively and qualitatively. Our model can be used to investigate the relationships between heart sound acoustic features and hemodynamic factors/anatomical parameters.


Heart Sounds/physiology , Hemodynamics/physiology , Models, Cardiovascular , Animals , Atrioventricular Block/physiopathology , Biomechanical Phenomena , Computational Biology , Computer Simulation , Computer Systems , Disease Models, Animal , Exercise/physiology , Heart Failure/physiopathology , Heart Valves/physiopathology , Humans , Mathematical Concepts , Phonocardiography/statistics & numerical data , Swine
10.
Int Heart J ; 62(5): 988-996, 2021 Sep 30.
Article En | MEDLINE | ID: mdl-34544968

In this study, we aimed to investigate the time course of new-onset complete atrioventricular block (CAVB) and its reversibility after transcatheter aortic valve implantation (TAVI). We analyzed 206 consecutive patients without baseline CAVB who underwent successful TAVI. The incidence of new-onset CAVB was determined to be 12.6% (26/206). Among these patients, 14 recovered from CAVB within 2 weeks (6.8%, 14/206), while the remaining 12 (5.8%, 12/206) underwent permanent pacemaker (PPM) insertion. Among the 12 patients who received the PPM, 4 were able to recover from CAVB within 4 months. Thus, only 8 among 206 patients (3.8%) showed persistent CAVB. Early-onset CAVB on the day of the procedure was the strongest predictor of PPM implantation (OR = 127). The electrocardiographic changes that occurred after TAVI were mostly recovered after 1 month. The most critical procedural factor that predicts CAVB and PPM insertion is the deep implantation (>4 mm) of a big valve (oversizing index >5.9%). In conclusion, the incidence of CAVB after TAVI was estimated to be at 12.6%. Two-thirds of these patients recovered from CAVB within 3 days, resulting in a final rate of persistent CAVB of 4%. To prevent CAVB, we have to implant an appropriate valve type with an optimal size and depth.


Aortic Valve Stenosis/surgery , Atrioventricular Block/etiology , Heart Valve Prosthesis Implantation/adverse effects , Transcatheter Aortic Valve Replacement/adverse effects , Age of Onset , Aged , Aged, 80 and over , Aortic Valve Stenosis/diagnosis , Atrioventricular Block/epidemiology , Atrioventricular Block/physiopathology , Atrioventricular Block/therapy , Electrocardiography/methods , Female , Heart Valve Prosthesis Implantation/methods , Humans , Incidence , Long QT Syndrome , Male , Pacemaker, Artificial/adverse effects , Predictive Value of Tests , Recovery of Function/physiology , Republic of Korea/epidemiology , Retrospective Studies , Risk Factors , Time Factors , Transcatheter Aortic Valve Replacement/instrumentation
11.
Int Heart J ; 62(5): 1012-1018, 2021 Sep 30.
Article En | MEDLINE | ID: mdl-34544981

High-degree atrioventricular block (HAVB) or complete heart block (CHB) is a common complication associated with transcatheter aortic valve replacement (TAVR). However, some patients with HAVB/CHB recover with time. The results of electrophysiological studies (EPSs) using permanent pacemaker implantation (PPI) in patients with suspicious HAVB/CHB are considered controversial.This study aimed to evaluate whether HAVB/CHB induction at the bedside using a temporary pacemaker can predict recurrence in patients who had recovered from HAVB/CHB after TAVR.We enrolled a total of 11 patients who had recovered from HAVB/CHB and evaluated their electrophysiology using right ventricular pacing and/or procainamide administration.HAVB/CHB induction was positive. Three patients tested positive for HAVB/CHB, whereas 8 tested negative. The ejection fraction and the interval between HAVB/CHB onset and EPS were found to be significant. HAVB/CHB positive patients underwent PPI. A patient with a balloon-expandable valve tested positive just before recovery of CHB, but tested negative 5 days later and was included in the negative group. The 4 patients who tested negative received a cardiovascular implantable electric device (CIED). We observed HAVB/CHB in 2 patients who had previously tested positive after 3 months. Among those who tested negative, those with CIED had no HAVB/CHB, and others showed neither HAVB/CHB on electrocardiogram nor experienced syncope or sudden death.Our EPS revealed that HAVB/CHB induction may predict HAVB/CHB recurrence after TAVR. Valve type and EPS timing may affect the results.


Aortic Valve Stenosis/surgery , Atrioventricular Block/chemically induced , Atrioventricular Block/therapy , Cardiac Electrophysiology/statistics & numerical data , Heart Valve Prosthesis/adverse effects , Transcatheter Aortic Valve Replacement/adverse effects , Administration, Intravenous , Aged , Aged, 80 and over , Anti-Arrhythmia Agents/administration & dosage , Atrioventricular Block/diagnosis , Atrioventricular Block/physiopathology , Bundle-Branch Block/physiopathology , Cardiac Electrophysiology/trends , Electrocardiography/methods , Female , Humans , Male , Pacemaker, Artificial/adverse effects , Point-of-Care Testing/trends , Predictive Value of Tests , Procainamide/administration & dosage , Recurrence , Retrospective Studies , Treatment Outcome
13.
Am J Physiol Heart Circ Physiol ; 321(3): H569-H576, 2021 09 01.
Article En | MEDLINE | ID: mdl-34355987

Ventricular arrhythmias, consisting of single ectopic beats (sEB), multiple EB (mEB), and torsades de pointes (TdP, defined as ≥5 beats with QRS vector twisting around isoelectric line) can be induced in the anesthetized chronic atrioventricular block (CAVB) dog by dofetilide (IKr blocker). The interplay between temporal dispersion of repolarization, quantified as short-term variability (STV), and spatial dispersion of repolarization (SDR) in the initiation and perpetuation of these arrhythmias remains unclear. Five inducible (≥3 TdPs/10 min) CAVB dogs underwent one mapping experiment and were observed for 10 min from the start of dofetilide infusion (0.025 mg/kg, 5 min). An intracardiac decapolar electrogram (EGM) catheter and 30 intramural cardiac needles in the left ventricle (LV) were introduced. STVARI was derived from 31 consecutive activation recovery intervals (ARIs) on the intracardiac EGM, using the formula: [Formula: see text]. The mean SDR3D in the LV was determined as the three-dimensional repolarization time differences between the intramural cardiac needles. Moments of measurement included baseline (BL) and after dofetilide infusion before first 1) sEB (occurrence at 100 ± 35 s), 2) mEB (224 ± 96 s), and 3) non-self-terminating TdP (454 ± 298 s). STVARI increased from 2.15 ± 0.32 ms at BL to 3.73 ± 0.99 ms* before the first sEB and remained increased without further significant progression to mEB (4.41 ± 0.45 ms*) and TdP (5.07 ± 0.84 ms*) (*P < 0.05 compared with BL). SDR3D did not change from 31 ± 11 ms at BL to 43 ± 13 ms before sEB but increased significantly before mEB (68 ± 7 ms*) and to TdP (86 ± 9 ms*+) (+P < 0.05 compared with sEB). An increase in STV contributes to the initiation of sEB, whereas an increase in SDR is important for the perpetuation of non-self-terminating TdPs.NEW & NOTEWORTHY This study compared two well-established electrophysiological parameters, being temporal and spatial dispersion of repolarization, and provided new insights into their interplay in the arrhythmogenesis of torsades de pointes arrhythmias. Although it confirmed that an increase in temporal dispersion of repolarization contributes to the initiation of single ectopic beats, it showed that an increase in spatial dispersion of repolarization is important for the perpetuation of non-self-terminating torsades de pointes arrhythmias.


Atrioventricular Block/physiopathology , Models, Cardiovascular , Torsades de Pointes/physiopathology , Action Potentials , Animals , Atrioventricular Block/complications , Dogs , Female , Male , Reaction Time , Torsades de Pointes/etiology
14.
Pacing Clin Electrophysiol ; 44(10): 1738-1742, 2021 Oct.
Article En | MEDLINE | ID: mdl-34463365

Leadless pacemakers have become a major breakthrough in the management of bradyarrhythmia as an attractive alternative to the standard transvenous pacemakers, but safety and long-term outcomes of the new Micra-AV, which is capable guarantee atrioventricular (AV) synchrony, have been poorly described. Hence, we describe how we managed a 57-year-old patient who developed pacemaker syndrome due to significant Micra-AV dyssynchrony. This case emphasizes how leadless pacemaker AV synchrony could be overestimated, thereby requiring a stepwise process leading to adequate device reprogramming. Holter-ECG monitoring and exercise test resulted to be valuable tools for an early detection of inadequate AV synchrony, integrating and completing device reports.


Algorithms , Atrioventricular Block/physiopathology , Atrioventricular Block/therapy , Pacemaker, Artificial/adverse effects , Prosthesis Failure , Electrocardiography , Electrocardiography, Ambulatory , Exercise Test , Female , Heart Rate , Humans , Middle Aged , Physical Exertion , Posture , Prosthesis Design
15.
Pacing Clin Electrophysiol ; 44(9): 1497-1503, 2021 Sep.
Article En | MEDLINE | ID: mdl-34287980

BACKGROUND: Radiofrequency catheter ablation remains the most effective management option for atrioventricular nodal reentry tachycardia (AVNRT). The risk of atrioventricular (AV) block requiring permanent pacemaker is substantial, but, currently, a reliable method to predict this complication is lacking. METHODS: The electrophysiologic studies (EPS) and baseline characteristics of patients who underwent catheter ablation for the treatment of AVNRT were retrospectively analyzed to investigate predisposing factors for AV block after treatment. Patients were followed for AV block at one month and one year after hospital discharge. RESULTS: Among 784 patients treated with catheter ablation for AVNRT between 1999 to 2019, 15 developed AV block. Patients with AV block were older (p = .001). Among the recorded EPS parameters, patients with AV block had significantly higher Atrial His interval (120 vs. 110 ms, p = .049), Wenckebach cycle length (WCL) (400 vs. 353 ms, p < .001) and tachycardia CL (400 vs. 387 ms, P = .01) during the ablation compared to their peers without AV block. Additionally, only WCL (OR = 1.1, 95% CI 1.02-1.19, p = .017) remained significant after adjustment for age, gender, ERP, AH interval, and HR. This association was confirmed by comparing patients with (n = 15) and without (n = 15) AV block using propensity score-matching. A WCL≥400ms was associated with a 4-fold higher incidence of AV block (4.79% vs. 1.25%). CONCLUSION: Increased pre-procedural WCL was associated with a high risk for AV block after catheter ablation treatment for AVNRT. These findings suggest that this readily available EPS-derived parameter may be a novel marker of risk for severe complications in these patients.


Atrioventricular Block/physiopathology , Catheter Ablation/methods , Postoperative Complications/physiopathology , Tachycardia, Atrioventricular Nodal Reentry/surgery , Electrocardiography , Electrophysiologic Techniques, Cardiac , Female , Humans , Male , Middle Aged , Retrospective Studies , Risk Factors , Tachycardia, Atrioventricular Nodal Reentry/physiopathology
18.
Am Heart J ; 241: 83-86, 2021 11.
Article En | MEDLINE | ID: mdl-34302751

SARS-CoV-2 infection has been associated with cardiovascular disease in children, but which children need cardiac evaluation is unclear. We describe our experience evaluating 206 children for cardiac disease following SARS-CoV-2 infection (one of whom had ventricular ectopy) and propose a new guideline for management of these children. Routine cardiac screening after SARS-CoV-2 infection in children without any cardiac signs or symptoms does not appear to be high yield.


Aftercare , COVID-19/physiopathology , Heart Diseases/diagnosis , Referral and Consultation , Adolescent , Ambulatory Care , Atrioventricular Block/diagnosis , Atrioventricular Block/etiology , Atrioventricular Block/physiopathology , Bradycardia/diagnosis , Bradycardia/etiology , Bradycardia/physiopathology , COVID-19/complications , Cardiology , Chest Pain/physiopathology , Child , Child, Preschool , Dyspnea/physiopathology , Echocardiography , Electrocardiography , Fatigue/physiopathology , Female , Heart Diseases/etiology , Heart Diseases/physiopathology , Humans , Hypertrophy, Left Ventricular/diagnosis , Hypertrophy, Left Ventricular/etiology , Hypertrophy, Left Ventricular/physiopathology , Hypertrophy, Right Ventricular/diagnosis , Hypertrophy, Right Ventricular/etiology , Hypertrophy, Right Ventricular/physiopathology , Implementation Science , Male , Pediatrics , Practice Guidelines as Topic , SARS-CoV-2 , Severity of Illness Index , Syncope/physiopathology , Ventricular Premature Complexes/diagnosis , Ventricular Premature Complexes/etiology , Ventricular Premature Complexes/physiopathology , Young Adult
20.
BMC Cardiovasc Disord ; 21(1): 289, 2021 06 11.
Article En | MEDLINE | ID: mdl-34116630

BACKGROUND: Nationwide data on the prevalence of atrioventricular (AV) block are currently unavailable in China. Thus, we aimed to assess the prevalence and risk factors of AV block among Chinese health examination adults. METHODS: A total of 15,181,402 participants aged ≥ 18 years (mean age 41.5 ± 13.4 years, 53.2% men) who underwent an electrocardiogram as a part of routine health examination in 2018 were analyzed. AV block was diagnosed by physicians using 12-lead electrocardiogram. Overall and stratified prevalence (by age, sex, and city size) of all, first-, second- and third-degree AV block were calculated. Multivariable logistic regression analyses were performed to explore risk factors associated with AV block. RESULTS: AV block was observed in 88,842 participants, including 86,153 with first-degree, 2249 with second-degree and 440 with third-degree AV block. The age- and sex-standardized prevalence rate [95% confidence interval (CI)] of all, first-, second- and third-degree AV block were 7.06‰ (7.01-7.11), 6.84‰ (6.79-6.89), 0.18‰ (0.17-0.18) and 0.04‰ (0.03-0.04) respectively. After multivariable adjustment, the risk of AV block was positively associated with older age, being male, lower heart rate, higher body mass index, hypertension, diabetes and low high-density lipoprotein cholesterol. High total cholesterol was associated with a lower risk of AV block. CONCLUSION: First-degree AV block is relatively common while severe AV block is rare in health examination adults. Besides, AV block was highly prevalent among the elderly. The risk of AV block was associated with older age, being male and metabolic factors.


Atrioventricular Block/epidemiology , Prevalence , Adolescent , Adult , Age Factors , Atrioventricular Block/diagnosis , Atrioventricular Block/physiopathology , China/epidemiology , Cross-Sectional Studies , Databases, Factual , Electrocardiography , Female , Heart Disease Risk Factors , Humans , Male , Metabolic Diseases/epidemiology , Middle Aged , Risk Assessment , Severity of Illness Index , Sex Factors , Time Factors , Young Adult
...